G506 Mask Automatic Filter Performance Tester
G506 Mask Automatic Filter Performance Tester

G506 Mask Automatic Filter Performance Tester

MOQ : 1 Unit

G506 Mask Automatic Filter Performance Tester Specification

  • Test Material
  • Meltblown Nonwovens, Cloth, Paper, Mask Material
  • Humidity
  • 10% - 85% RH adjustable
  • Temperature
  • Room Temperature (15C - 35C)
  • Test Range
  • 0.1 - 99.9% Filtration Efficiency
  • Gas Pressure
  • 0.1 - 0.6 MPa
  • Port Size
  • 80 mm clamp
  • Specimen Size
  • Up to 210 mm diameter
  • Number of Specimens
  • 1 per test
  • Type
  • Automatic Filter Performance Tester
  • Material
  • Stainless Steel, High Grade Plastic
  • Power
  • 800W
  • Power Source
  • Electric
  • Dimension (L*W*H)
  • 680mm x 620mm x 1180mm
  • Weight
  • 85 kg
  • Usage
  • Mask Filtration Efficiency Testing
  • Application
  • Filter Media, Mask, Respirator Quality Inspection
  • Data Output
  • USB Port, Printer
  • Particle Size Range
  • 0.3 m
  • Test Flow Rate
  • 10 - 120 L/min adjustable
  • Filtration Test Medium
  • NaCl and Oil-mist Aerosol
  • Test Standards
  • GB 2626, EN 149, NIOSH 42 CFR Part 84, etc.
  • Detection Principle
  • Aerosol Photometer
  • Operation Mode
  • Automatic & Manual Modes
  • Noise Level
  • 65 dB
  • Voltage
  • 230V / 50Hz
  • Display
  • 7 inch Touch Screen
 

G506 Mask Automatic Filter Performance Tester Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 10 Units Per Month
  • Delivery Time
  • 5-7 Days
 

About G506 Mask Automatic Filter Performance Tester



Last Chance! Elevate your testing arsenal with the Brilliant G506 Mask Automatic Filter Performance Tester-a Spectacular masterpiece designed for precision and reliability. Ideal for exporters, manufacturers, and suppliers in China, this advanced instrument offers both automatic and manual operation modes. Pick Yours today to measure filtration efficiency (0.1-99.9%) in meltblown nonwovens, cloth, paper, and mask materials. With a 7-inch touch screen, USB data output, and compliance with GB 2626, EN 149, and NIOSH 42 CFR Part 84, this stainless steel and high-grade plastic tester ensures outstanding accuracy and lasting durability. Offer valid while stocks last!

Versatile Applications for Quality Assessment

The G506 Mask Automatic Filter Performance Tester is not only engineered for mask filtration efficiency testing but also excels in analyzing various filter media, respirators, and related materials. Its adaptable design accommodates specimen sizes up to 210 mm diameter, making it suitable for quality inspection across a broad range of applications-including meltblown fabrics, cloths, and papers. Equipped to test oil-mist and NaCl aerosols, this device delivers consistent, reliable results on multiple surface types-ensuring product safety and compliance.


Global Export Markets and Hassle-Free Transactions

The G506 Tester is in high demand across key export markets, with samples available to evaluate before making your proposal amount. Flexible payment terms help optimize your expenditure while our streamlined packing & dispatch system guarantees secure, timely delivery. Whether you're an international buyer or a regional distributor, this instrument meets rigorous global standards-making it a strategic investment for businesses seeking comprehensive filtration quality assurance. Don't miss out on this high-performance testing solution!


FAQ's of G506 Mask Automatic Filter Performance Tester:


Q: How does the G506 Mask Automatic Filter Performance Tester determine filtration efficiency?

A: The G506 uses the aerosol photometer detection principle to measure filtration efficiency, accurately analyzing particulate reduction by evaluating the passage of NaCl or oil-mist aerosols through the test material.

Q: What materials and specimen sizes can be tested with this device?

A: You can test meltblown nonwovens, cloth, paper, and various mask materials with specimen diameters up to 210 mm, ensuring versatility across different quality inspection needs.

Q: When is automatic or manual operation mode recommended for use?

A: Automatic mode is ideal for routine, high-throughput testing, while manual mode offers greater control and customization during complex or specialized assessments.

Q: Where can the data output from the G506 be accessed?

A: Test data can be accessed via the 7-inch touch screen display, USB port for digital export, or through the built-in printer, enabling convenient record-keeping and analysis.

Q: What are the benefits of using the G506 in mask and filter media quality inspection?

A: The G506 offers highly accurate, reliable, and repeatable results, ensuring compliance with industry standards such as GB 2626, EN 149, and NIOSH 42 CFR Part 84-making it indispensable for quality assurance and regulatory conformity.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Mask And Protective Cloth Tester Category

Protective Clothing Chemical Liquid Penetration Resistance Tester

Protective Clothing Chemical Liquid Penetration Resistance Tester

Minimum Order Quantity : 1 Unit

Number of Specimens : Up to 2 per test cycle

Specimen Size : 75 mm diameter

Dimension (L*W*H) : 600 x 450 x 500 mm

Port Size : Standard 6 mm quickconnect

Gas Pressure : Adjustable, up to 100 kPa

Protective Clothing Splash and Spray Liquid Tightness Tester

Protective Clothing Splash and Spray Liquid Tightness Tester

Minimum Order Quantity : 1 Unit

Number of Specimens : 1 specimen per test

Specimen Size : Up to 2000 mm length clothing sample

Dimension (L*W*H) : Approx. 760 x 510 x 1350 mm

Port Size : Standard air inlet port 8 mm

Gas Pressure : 0.050.08 MPa

Infectious Disease Portable Test Sampling Booth

Infectious Disease Portable Test Sampling Booth

Minimum Order Quantity : 1 Unit

Number of Specimens : Single Specimen Per Operation

Specimen Size : Standard Swab Tube (10 mm x 100 mm max)

Dimension (L*W*H) : 1200mm x 1000mm x 2000mm

Port Size : 150 mm Diameter Glove Ports

Gas Pressure : Ambient/Atmospheric Pressure (Nontoxic, Normal Room Air)



arrow